Door AccessUbiquiti / UniFi

UniFi Enterprise Access Hub

  • hub
  • Maputo

Ubiquiti Eah 8 by order in Maputo. Send the equipment model, installation details, photos and quantity to confirm compatibility before purchase.

Overview

Brand
Ubiquiti / UniFi
Category
Door Access
Subcategory
hub
Availability
By order in Maputo

Main Specifications

Ambient Operating Humidity
5 to 95% noncondensing
Ambient Operating Temperature
0 to 40° C (32 to 104° F)
Buttons
(1) Factory reset
CAN/ULC 60839 11 1 Grade
Grade assignment: I
Certifications
CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Digital Input
(8) Inputs for request-to-exit devices (8) Inputs for door position sensors (1) Emergency
Dimensions
379 x 355 x 105 mm (15 x 14 x 4.1")
Document Number, And Issue Date And/or Revision Level
EAH-8, Ver 01
Dry Output Relay
(8) Lock terminals (12V or Dry) (4) AUX terminals for advanced setup (Chime/Siren/Door opener)
Enclosure Material
SGCC steel housing with polycarbonate cover
Indoor And Outdoor Use
Indoor only
Input Terminals
(8) Door exit request (8) Door position (1) Emergency
LEDs
W/B Learn More
Management Application
Access
Max. PoE Wattage Per Port
30W
Max. Power Consumption
240W
Maximum User Count
10,000
Mount Material
SGCC steel
Mounting
Wall
NDAA Compliant
Networking Interface
(10) 10/100/1000 Base-T
Other Locks (1A)
24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
PoE Cabling Requirements
Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for pat
PoE Interface
(8) PoE+ outputs, 50V DC, 30W per port (Max 190W aggregated)
Power Method
Universal input, 100–240V AC, Max. 4.4A, 50/60 Hz 32–48V DC Lead Acid Battery, Max. 7.5A @32V
Power Supply
AC/DC, internal
Powered Output Relay
Lock: 12V DC, 1A/ Dry Aux: Dry only
Software Information
The software version can be checked at https://unifi.ui.com
Supported Doors
8
UA Lock Electric (400mA)
24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA Lock Magnetic 270kg (800mA)
24 AWG length: 12 m (39 ft) 22 AWG length: 20 m (66 ft) 20 AWG length: 30 m (98 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
UA Lock Magnetic 540kg (500mA)
24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UL 294 Level
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
UL 294 Statement
Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
Weight
Device: 9.1 kg (20 lb) Mount: 624 g (1.4 lb)

Compatibility

Use 1
Ubiquiti / UniFi